Difference between revisions of "Stone Heat Furnace"
(+ add Interface, text) |
(→Interface: Interface) |
||
Line 20: | Line 20: | ||
==Interface== | ==Interface== | ||
[[File:Stone Heat Furnace Interface.png]] | [[File:Stone Heat Furnace Interface.png]] | ||
+ | |||
+ | |||
+ | === Internal/External Control (A) === | ||
+ | |||
+ | If set to internal control, you can move the Gauges yourself. If set to external, the Gauges are controlled by a signal coming in over a [[Signal Cable]] | ||
+ | |||
+ | === Take/Decline Fuel (B) === | ||
+ | |||
+ | If under Internal control, this controls whether the Furnace will consume fuel. If it is left off, the furnace won't consume any fuel. | ||
+ | |||
+ | |||
+ | === Regulator Slot (C) === | ||
+ | |||
+ | Normally only the Control Gauge can be controlled. If you have a [[Regulator]] installed, you may be able to set a particular temperature for the furnace to hold. | ||
+ | |||
+ | === Combustion Chamber Slot (D) === | ||
+ | |||
+ | At least 1 [[Combustion Chamber]] is needed for the Stone Heat Furnace to work. Add a second to improve efficiency. | ||
+ | |||
+ | === Fuel Slot (E) === | ||
+ | |||
+ | Insert combustible fuel here. | ||
+ | |||
+ | |||
+ | === Temperature Gauge (F) === | ||
+ | |||
+ | Shows the current temperature of the furnace. Requires a regulator to be able to be controlled. | ||
+ | |||
+ | ===Control Gauge (G) === | ||
+ | |||
+ | Sets the rate at which to burn fuel in %. At a setting under 10%, no fuel will be burned, and the Furnace is effectively off. |
Revision as of 02:10, 28 June 2015
The Stone Heat Furnace provides heat either direct to other blocks or via Copper Thermal Cable. They are typically used to create a heat gradient for Turbines.
Contents
Crafting
Stone Heat Furnace
Interface
Internal/External Control (A)
If set to internal control, you can move the Gauges yourself. If set to external, the Gauges are controlled by a signal coming in over a Signal Cable
Take/Decline Fuel (B)
If under Internal control, this controls whether the Furnace will consume fuel. If it is left off, the furnace won't consume any fuel.
Regulator Slot (C)
Normally only the Control Gauge can be controlled. If you have a Regulator installed, you may be able to set a particular temperature for the furnace to hold.
Combustion Chamber Slot (D)
At least 1 Combustion Chamber is needed for the Stone Heat Furnace to work. Add a second to improve efficiency.
Fuel Slot (E)
Insert combustible fuel here.
Temperature Gauge (F)
Shows the current temperature of the furnace. Requires a regulator to be able to be controlled.